Specify the tolerance as a percentage of a stated nominal weight, and start at about ±5% on a 100–400 kg (220–880 lb) sand cast counterweight. Go tighter only when the machine’s own limit requires it. We found no standard that sets a weight tolerance for counterweights, so the ±5% comes from general casting tables.
The ±5% assumes a cast weight fitted to a machine, where the weight is the working figure. Calibration and test weights belong to a far tighter scale.
The job can change the direction of the limit as well as its size, because each machine depends on the weight in a different way:
- Cranes and other machines rated on a load chart: write the limit one-sided, plus only and minus 0, because a light piece leaves the machine short of what its chart assumes.
- Traction elevators: work from the overbalance range on the data plate, which limits the stack in both directions.
- Tractor ballast for EU type approval: keep the marked mass accurate to ±5%, the figure the regulation sets.
What Weight Tolerance a Sand Cast Counterweight Can Hold
A sand cast counterweight of 100–400 kg (220–880 lb) can be held to about ±5%, and closer on a molding machine in long runs. The figures below come from Russian and Chinese casting standards, the only mass tolerance tables we could read.
Both standards state a total band, so a 10% band means ±5%.
GOST R 53464-2009, the Russian standard in force, recommends classes 8 to 15 for as-cast ferrous parts of 100–1,000 kg in green sand at 3.5–4.5% moisture or liquid self-hardening mixes. At 100–400 kg, those classes run from a 3.2% band (±1.6%) to a 32% band (±16%). The low end is for simple compact castings in automated mass production, and the high end is for complex large one-offs.
A counterweight is simple and compact but rarely made in automated mass production, so the standard names no single class for it. GOST class 11, near the middle, is a 10% band (±5%) at 100–400 kg. Outside that range, start from the same class: ±6% at 40–100 kg, ±4% at 400–1,000 kg and ±3.2% at 1,000–4,000 kg.
China’s GB/T 11351-89 splits the same question by process. For gray iron at 100–400 kg, GB/T 11351-89 gives about ±2.5% to ±4% for machine or shell molding in large batches. For gray iron at the same weight in self-hardening sand in small batches, GB/T 11351-89 gives about ±5% to ±7%. That edition is withdrawn and the 2017 edition changed the values, so use the 1989 figures as a scale only.
How to Set the Tolerance From the Counterweight’s Job
Find the check that depends on the weight, and work out how far the weight can move before that check fails. We found no published rule that turns a job into a percentage, so the number has to come from your own machine’s data.
Run the check at the lightest and the heaviest weight you could accept. The largest deviation that still passes is your limit. Convert it to a percentage of nominal weight:
Tolerance (%) = allowable weight deviation ÷ nominal weight × 100
Compare the result with the casting figures above. If your number is looser than what the process holds, write your number. If it is tighter, every piece has to be weighed and sorted. Settle that with the foundry before the pattern is built.
Crane Counterweights
On a crane, the capacity chart sets the limit. Manitowoc’s auxiliary counterweight folio for the 4100W Series-3 limits each 46,000 lb (20,866 kg) box to plus 700 lb (318 kg) and minus 0 lb, about +1.5% / −0.
The folio’s limit for a stack is the box limit added up: 8 boxes × 700 lb gives plus 5,600 lb on the 368,000 lb set. Divide a stack’s allowance by its piece count in the same way. The folio dates from 1995, is marked reference only and covers steel boxes filled with scrap iron and concrete. Use it to see how a builder writes a limit. Do not treat +1.5% as a target for a casting.
Elevator Counterweights
On a traction elevator, the design overbalance sets the limit. The elevator code puts the allowed maximum and minimum on a data plate. A weight error on the counterweight moves the overbalance by this amount:
Overbalance shift (percentage points) = counterweight weight error ÷ rated capacity × 100
Forklift Counterweights
On a forklift, the truck maker sets the limit. OSHA 1910.178 bars added counterweight unless the truck manufacturer approves it. A buyer replacing a weight therefore works to the maker’s figure. If you build the truck, run the method above against its rated capacity.
Tractor Ballast
On tractor ballast, EU Regulation 2015/208 requires the mass marked on ballast weights needed for EU type approval to be accurate to ±5%. The rule does not apply in the US.
What Nominal Weight the Tolerance Applies To
Measure the tolerance from the weight the machine needs, written on the drawing as a calculated weight. GB/T 11351 also allows a nominal taken from weighed castings. That centers the tolerance on what the foundry poured, which suits a housing but can leave a counterweight short of the weight the machine needs.
Where the nominal is a calculated weight, write the density on the drawing.
State the condition of the part as well. Nominal weight under GB/T 11351-89 includes machining allowance, so it is the as-cast weight. A counterweight works at its finished weight, so tie the tolerance on a machined piece to the finished weight. Say too whether the piece is weighed before or after paint.
Whether to Use a Plus-Minus or One-Sided Tolerance
Use a one-sided tolerance, plus only and minus 0, when a light counterweight would fail the machine’s check and a slightly heavy one would not. Use plus-minus when both directions matter or when the figure only describes the weight.
The plus limit stays because too much counterweight is a fault too. A +5% / −0 limit is a 5% band, half the width of a ±5% limit. A process that holds a 10% band needs the whole band on the plus side, with the foundry aiming above nominal. Check that the machine accepts the heaviest piece.
Unequal limits are a third option, with more room above nominal than below. The 1989 edition of GB/T 11351 allowed them.
How to Write the Tolerance on the Drawing or Order
Write the tolerance as a note on the drawing, and repeat it on the purchase order. Put the acceptable weight on the RFQ too, as an actual weight where you have one.
The note needs four items:
- Nominal weight: the figure in lb and kg, with the density if it is calculated.
- Limits: the plus and the minus, as percentages or weights, even when one of them is 0.
- Condition: as cast or finished, and before or after paint.
- Piece and stack: the limit for each piece, plus a limit for the set if the pieces work as a stack.
A 200 kg piece at ±5% could read: “Nominal finished weight 200 kg (441 lb), calculated at [density] g/cm³, before paint. Tolerance ±5% per piece (190–210 kg).”
Write percentages rather than a bare grade. If an offshore foundry quotes “MT Grade 10”, or “MT Grade 10/8” for unequal limits, ask which edition of GB/T 11351 it means. Put the percentages on the order.